Cameras for indirect detection (>20 keV)
Our partnerAndor Oxford Instruments

Cameras for indirect detection (>20 keV)

iKon HF and Zyla HF from Andor Technology

For harder high-energy photons or particles from about 14 keV to 100 keV cameras with indirect detection methods are preferred. Indirect detection employs a material, such as a scintillator or phosphor, to convert incident X-ray photons or electrons to photons of a visible wavelength which are then detected by the sensor. We offer CCD and sCMOS technology according to their individual advantages in noise and frame rate performance.

Features
  • Back-illuminated CCD and sCMOS technology with coupled fiber optics window
  • 13,5 µm and 6,5 µm pixel size
  • Thermo-electrical cooling down to -35 °C for negligible dark current
  • High quality 16 bit AD converter for low readout noise
  • Optional beryllium window and scintillator screens

Further information

Indirect imaging of high energy photons and particles is highly efficient when light from the scintillator goes straight to the sensor. Direct bonding of a fiber optic plate to the CCD or sCMOS sensor facilitates a compact optical geometry with minimum loss of light. Depending on the experimental requirements regarding field of view, frame rate and noise performance we offer either the iKon-L HF CCD camera or the Zyla HF sCMOS camera. Scintillator screens with high throughput or high transmission can be added as an option. A beryllium window can be inserted if visible light has to be blocked. The iKon and Zyla detectors are fully integrated into the EPICS control software that is commonly used in larger facilities with real-time beam monitoring.

Specification

pdf
iKon-L_HF.pdf
1.70 MB
iKon-L HF 936 (2048 x 2048 x 13 µm)
pdf
Zyla_5.5_HF.pdf
5.71 MB
Zyla 5.5 HF (2560 x 2160 x 6.5 µm)

Applications

Electron microscopy
X-ray diffraction
Neutron tomography
Plasma diagnostics
X-ray tomography

Downloads

Scintillators for high energy detection
Scintillators for high energy detection
Detection of high energy radiation
Detection of high energy radiation
Software
Software
Liquid cooling system EXT-440
Liquid cooling system EXT-440

Videos

Reference customers

TitleAuthor(s)InstituteYearSpectrograph/Detector
Three-dimensional phase sensitive X-ray imaging
of fatigue damaged carbon-fiber-reinforced polymers
Hildebrand, M. LeckDepartment of Analytical Measurement Technology, Faculty of Natural Sciences and Technology,
University of Applied Sciences and Arts Göttingen
2016Zyla-5.5X-FOR
EMCCD based Single Photon Emission Microscope System for I-125 Imaging in Small Animals L. J. Meng Nuclear, Plasma and Radiological Engineering, University of Illinois, Urbana, USA2007

iXon DF897-FB

Contact

Stephane Struyve
Stephane Struyve

Contact

Quantum Design GmbH

Meerstraat 177
B-1852 Grimbergen
Belgium

Phone+32 230 84324
Mobil:+32 495 797175
E-mail:benelux@qd-europe.com
Cookie notice Cookies help us in providing our services. By using our services, you agree to the use of cookies. Privacy policy
Stephane StruyveSales Manager
+32 2 3084324
stephane.struyve@qd-europe.com