Luminaire blue light hazard spectroradiometer
ISR300-PSL from BenthamThe ISR300-PSL is a key tool in the accurate evaluation of blue light hazard across all classes of lighting products.
CE marking of luminaires against the EU low voltage directive 2014/35/EU requires implementation of EN 60598-1 according to which blue light hazard should be assessed with reference to IEC TR 62778.
The ISR300-PSL offers the luminaire manufacturer the most reliable and accurate direct assessment of blue light hazard, devoid of overly conservative assessment results caused by employing an approach based on calculation and estimation.
- High accuracy telespectroradiometer
- Direct determination of blue light radiance in 11mrad field of view
- Calibrated spectral radiance standard traceable to PTB, Germany
- Fully automated over USB 2.0 with BenWin+ spectral acquisition software
- Software guidance, calculation and report generation with PSL Wizard application
Further information
Core benefits
- Direct approach to blue light hazard testing
- Assess all classes of lighting product
- No dark room or knowledge of standards required
- A key tool in designing lighting products for compliance
Reported parameters
- Spatially-averaged spectral radiance
- Spatially-averaged blue light radiance
- Threshold illuminance, Ethr
- Threshold distance, dthr
Specifications
Electro-optical
Spectral range of operation | 300-780 nm |
Spectral data interval | 5 nm |
Spectral bandwidth (FWHM) | 5 nm |
Wavelength accuracy | ± 0.3 nm |
Wavelength reproducibility | ± 0.05 nm |
Stray light rejection at 2.5 FWHM | 10-4 |
Photo-detectors | Multi-alkali PMT and Silicon photodiode |
Photo-current measurement | Dual-channel six decade picoammeter |
Measured quantity | Spectral radiance |
Minimum measurement distance | 200 mm |
Maximum measurement distance | >10 m |
Fields of view | 11, 5 and 1.7 mrad |
Range of blue light radiance (typ.) | 10-100000 W.m-2.sr-1 |
System requirements
Bench space | 0.5x 0.5 m not including working space for computer and luminaire under test |
Applications
- IEC TR 62778, “Application of IEC 62471 for the assessment of blue light hazard to light sources and luminaires”
- EN 60598-1:2015, "Luminaires - Part 1: General requirements and tests"
- IEC 62471:2006, "Photobiological safety of lamps and lamp systems"
- EN 62471:2008, Photobiological safety of lamps and lamp systems
- EU Low Voltage Directive, 2014/35/EU