McIlwain TC752 from CLE

The McIlwain TC752 tissue chopper has been specifically developed for the preparation of microscopic sections of small and irregularly shaped samples (biopsy, small organs etc.). The special design of the instrument ensures that the tissue is sectioned with a minimum of functional disturbance, and facilitates the repeatable preparation of tissue sections.

Features
  • Rapid sectioning with a minimum of functional disturbance
  • Infinitely variable section thickness
  • Sectioning of tissue into cubes or prisms

Further information

For tissue preparation with the McIlwain TC752 tissue chopper the sample is placed on a stainless steel table and affixed to a plastic disc. The table with the sample is automatically moved underneath the chopping arm at a user-preset speed. While the sample moves together with the table, the chopping arm cuts through the sample from top to bottom. Speed and number of sections can be set within a range of one to 200 sections per minute. The McIlwain tissue chopper cuts sections, cubes or prisms with an edge length of up to 1 mm within 30 seconds. The section thickness can infinitely be adjusted with the help of a micrometer gauge. To cut prisms, the table is returned to its initial position after the first cut and the sample stage is turned by 45°. Cubes are obtained by rotating the table through 90°.  A rapid return feature ensures short preparation times.

Downloads

Gewebeschneider TC752

Contact

Patricia Reinecke
Patricia Reinecke

Related products

Critical-point dryer
Critical point dryer K850 combines versatility and ease of operation. Built-in thermo-electric heating and adiabatic cooling allow precise temperature control. The vertical pressure chamber (32 mm in ...
Manual critical-point dryer
Quorum’s critical point dryer model E3100 is well-established in many laboratories and has been used successfully for more than 40 years.  Large valves and two large display instruments for pressure ...
Cryo preparation system for scanning electron microscopy
The cryo preparation system allows the analysis of wet samples with scanning electron microscopy (SEM) at temperatures down to -190 °C. During cryo preparation, samples are frozen rapidly and fed ...

Contact

Quantum Design AG

Route du Roule 41
CH-1723 Marly
Switzerland

Phone:+41 21 8699-033
E-Mail:suisse@qd-europe.com
Patricia ReineckeAdministration and Sales Support
+41 21 8699033
Write e-mail