Hall probes for gaussmeters and teslameters
From Lake Shore CryotronicsAxial, transverse, multi-axis, gamma, and tangential Hall probes are offered for the measurement of magnetic flux density. You can choose from a wide range of lengths and thicknesses. There are also probes available for cryogenic applications.
- 3-axis (vector), transverse, and axial models
- Handheld and fixture-mountable versions
- Unique designed probes
Weitere Informationen
All available Hall probes are either compatible with the new generation of gaussmeters, systems F41 and F71, or the old generation of teslameters, models 475 and 425. Hall probes of the FP series are compatible with the F41 and F71 Hall measurement systems while Hall probes of the 400 series are compatible with teslameter models 475 and 425. See below a table of the stocked probes and their major specifications.
400 series Hall probes - based on InAs - compatible with models 475 and 425
Sensor orientation | Frequency range | Stem material | Probe part number |
Axial orientation | DC to 400 Hz | Aluminum | HMMA-2504-VF |
Axial orientation | DC to 800 Hz | Fiberglass | HMNA-1904-VF |
Axial orientation | DC to 10kHz | Aluminum | HMMA-20504-VR |
Axial orientation | DC to 20kHz | Fiberglass | HMNA-1904-VR |
Transversal orientation | DC to 400Hz | Aluminum | HMMT-6J04-VF |
Transversal orientation | DC to 800 Hz | Fiberglass | HMNT-4E04-VF |
Transversal orientation | DC to 800 Hz | Aluminum | HMMT-6J04-VR |
Transversal orientation | DC to 20kHz | Fiberglass | HMNT-4E04-VR |
FP series Hall probes - based on 2DexTM - compatible with models F41 and F71
Sensor orientation | Frequency range | Stem material | Probe part number |
Axial orientation | DC to 10kHz | Aluminum | FP-2X-250-AS15 |
Transversal orientation | DC to 10kHz | Aluminum | FP-2X-250-TS15 |
3-axis | DC to 10kHz | Aluminum | FP-2X-250-ZS15 |
The probes can be differentiated by their detecting geometry, which is either axial, transversal or 3-axis (FP series only).
Transverse probes, most often rectangular in shape, measure fields normal to their stem width. They are useful for most general-purpose field measurements and are essential for working in magnet gaps. We offer several stem lengths and thicknesses as standard probes.
Axial probes, usually round, measure fields normal to their end. They can also be used for general-purpose measurements but are mostly used to measure fields produced by solenoids. We offer several stem lengths and diameters as standard probes.
The design of 3-axis probes is like that of the transverse probes. However, they deliver full vector field measurements in all three axes.
Aluminum as stem material is the best choice for DC and low-frequency AC measurements. Non-ferrous metals are used for probe stems, because they provide the best protection for the delicate Hall effect sensor without altering the measured field. However, metal stems have one drawback: they create eddy currents when placed in AC fields. These eddy currents oppose the field and cause measurement errors. Non-metallic fiberglass stems are used for higher frequency AC fields and for measuring pulse fields. Though this means less protection for the sensor, eddy currents are avoided so the frequency range of these probes is not limited.
We offer different Hall probe designs including:
- Axial, transversal and 3-axis orientation
- Stems from aluminum, fiberglass, flexible PCB and stainless steel
- Probes for cryogenic applications
- Various stem lengths (5 cm, 15 cm, 30 cm and 150 cm)
- Handheld and mountable probes
Spezifikationen
- Compatible with gaussmeters F41 and F71
- Wide field range
- 2Dex™ sensors with tiny active area
- built-in temperature and linearity (field) compensation
- Versatile handle and stem options
- active area and polarity indicators
- Application-specific probe customization available
- Compatible with teslameter models 475 and 425
- Flexible probe configurations
- Several sensor types available
- Field levels from earth field to very large electromagnets
- Application-specific probe customization available
Downloads
Kontakt
Navigation
Kategorien
Kontakt
Quantum Design AG
Route du Roule 41
CH-1723 Marly
Switzerland
Telefon: | +41 21 8699-033 |
E-Mail: | suisseqd-europe.com |