Our partner Lake Shore Cryotronics environment by Janis

CryoComplete

from Lake Shore Cryotronics

The CryoComplete is a turnkey solution for electrical measurements in cryogenic environments.

Features
  • VPF-100 LN2 reservior cryostat (77 K to 500 K)
  • Model 335 temperature controller
  • Calibrated silicon diode
  • M81-SSM-4 with BSC-10 and VM-10
  • PC with MeasureLink™

Further information

The CryoComplete is designed as turnkey solution. While easy to use, the system’s performance doesn’t disappoint. Its industry-leading measurement electronics promote low-level DC measurements and three full channels of lock-in AC capability—the keys to unlocking difficult measurements. Best of all, our cryogenic experts have designed CryoComplete from top to bottom, using cryogenic best practices, to deliver end-to-end system specifications.

Standard system capabilities:

  • VPF-100 cryostat with model 335 temperature controller and calibrated silicon diode:
  • Operating temperature range: 77 K to 500 K​
  • Cryogen: Liquid nitrogen
  • Sample environment: Sample-in-vacuum
  • Temperature stability: 50 mK
  • Pour-fill reservoir capacity: 1.2 L LN2
  • Cooldown time: 15 min to 77 K
  • Working time: 8 h
  • Optical ports: 4 quartz windows
  • Electrical sample mount: Pre-wired mounting plate with 8 contact pins

Resistance/I-V measurements​:

  • Measurements: 100 µΩ to 1 GΩ* ​
  • Source modes: DC, sine, triangle, square​
  • Source ranges: 1 pA to 100 mA​
  • Source frequency: 100 µHz to 100 kHz (square <5 kHz)​
    *Upper impedance range limited to DC
  • Measurement limit: 10 V maximum​
  • Input impedance: >10 GΩ (differential)
  • Leakage current at sample: 50 pA at 10 V for coaxial or 50 fA at 10 V for guarded triaxial
  • Voltage noise at sample: <5 nV/√Hz at 83 Hz
  • Measure noise at sample (1/f): <100 nV

 

 

Measurement benefits

Common measurements

 

 

Simultaneous source/ measure

Synchronous source/ measure

Low-noise source/ measure

Dual AC/DC sourcing

Lock-in autoranging

Differential conductance, low-frequency

Differential conductance, high-frequency

Resistance, low-temperature

I-V characteristics

Thermal conductivity

Thermal transport

1D materials, thermoelectric materials

X

X

 

 

 

X

 

 

 

X

Materials research

Nanodevices, superconducting devices, nonlinear devices

 

 

X

 

 

X

X

X

X

 

Materials development

Linear systems, sensors

 

 

X

 

 

 

 

 

 

 

Downloads

CryoComplete
The Beginner’s Guide to Cryostats and Cryocoolers

Contact

Stephane Struyve
Stephane Struyve

Contact

Quantum Design GmbH

Meerstraat 177
B-1852 Grimbergen
Belgium

Mobil:+32 495 797175
E-mail:beneluxqd-europe.com
Stephane StruyveSales Manager
+32 495 79 71 75
Write e-mail