AC Resistance Bridge
From Lake Shore CryotronicsBy using alternating current (AC) measurement in tandem with a specially designed internal lock-in amplifier, the Model 372 can extract very small measurement signals from background noise. This allows for much lower excitation levels to be used when compared to traditional direct current (DC) systems, minimizing the amount of energy that is dissipated into the device under test.
The Model 372, originally designed as Lake Shore’s best temperature measurement and control bridge, is perfectly suited for highly precise resistance measurements. It covers an impressive resistance range, from Milli-Ohm to several dozens of Mega-Ohm
- Reduces measurement noise due to patented technology
- Current source with integrated amplifier
- Excitation current from 1 pA
- Single channel AC resistance bridge with optional scanners
- Benchtop unit with either front panel or remote control
Further information
Externally generated electronic noise can be a major cause of self-heating if it can couple into the device under test. Thankfully, multiple noise-rejection strategies have been implemented to reduce this effect substantially:
The patent (U.S. Patent #6,501,255, Dec., 2002, “Differential current source with active common mode reduction,” Lake Shore Cryotronics, Inc.) balanced noise-rejecting current source ensures that external signals have no path to ground through the measurement circuit, effectively making the Model 372 unaltered by these noise sources.
The measurement signal cables use a driven guard that reduces parasitic capacitance in the cables that connect a scanner to the Model 372. This helps to further balance the measurement network and bolster the integrity of the noise rejection circuitry.
All measurement circuitry is isolated from other instrument components, limiting the impact of any small electrical disturbances.
The AC frequency options used for the measurement signal are selected to be naturally resilient to the 50 Hz or 60 Hz line frequencies.
Specifications
Model 372 AC Resistance Bridge
- Measurement input: AC, 4-lead differential, resistance
- Resistance: 2 mΩ to 63 MΩ in 22 ranges
- Excitation current: 1 pA to 31 mA (RMS)
- Maximum input voltage noise: 10 nV/rt(Hz) at 10 Hz
- Number of display readings: 1 to 8
- Interfaces: IEEE-488, USB, ethernet
Downloads
Contact
Navigation
Categories
Contact
Quantum Design GmbH
Eszak u. 24
H-1038 Budapest
Hungary
Phone: | +36 1 2402711 |
Fax: | +36 1 2402711 |
E-mail: | hungary@qd-europe.com |