CO2 laser spectrum analyzer

From Macken

The CO2 Spectrum Analyzer is a unique grating spectroscope which simultaneously displays all the lasing transactions of a CO2 laser. It is calibrated both in wavelength and rotational line designation to permit easy identification of 140 possible laser transitions between 9.1 and 11.3 µm. These transitions are visually displayed through the use of a UV excited thermal sensitive screen which darkens in the area struck by the IR laser beam.

The spectrum analysis screen has a response time of 1/4 seconds and permits the instrument to resolve all the CO2 rotational lines. The Model 16-A is light, portable and can easily be introduced into laboratory setups.

Features
  • Laser wavelength visually displayed
  • 9.1 µm - 11.3 µm special range
  • Identification of over 140 rotational lines

Further information

Wavelength Scale

This is a portion of the wavelength scale shown at full size. The upper calibrations are CO2 rotational line designations and the lower scale is the wavelength in microns. The thermal sensitive screen in the center displays the lasing wavelengths as a dark line.

The wide sensitivity range of the spectrum analysis screen can simultaneously display lines which differ in power density by a factor of 20. Each instrument is factory calibrated and should never need adjustment. However, a simple procedure allows the calibration to be checked by the user.

During operations, the laser beam is allowed to strike the front of the Spectrum Analyzer so that a portion of the beam passes through a variable slit. Normally the laser beam is intense enough that it is not necessary to focus the light on the slit. The light which does not pass through the slit is absorbed in the matte anodized case.

The internal beam monitor is a Thermal Imaging Plate that displays the CO2 laser beam which has passed through the slit. During the positioning of the instrument this device is engaged. When the monitor indicates the Analyzer to be properly positioned, it is then disengaged to allow the beam to pass onto the display screen.

Specification

Specifications Model 16A
Wavelength Range 9.1 to 11.3 µm
Resolution 0.003 µm (0.3 cm-1)
Maximum Power 100 watts
Minimum Power (focused) 0.01 watts
Screen Response Time 25 sec
Length 45,7 cm
Width 25,2 cm
Minimum Height 16,5 cm
Elevation of Slit 5,7 to 9,7 cm (adjustable)
Electrical Power 230 V, 50 HZ, 10 watts
12C16O2 Vibrational-Rotational Lines Identified 0001 - 0200 P2 to P60 & R2 to R62
0001 - 1000 P2 to P56 & R2 to R60
0111 - 1110 P19 to P45