Our partner Lake Shore Cryotronics

AC Resistance Bridge

From Lake Shore Cryotronics

By using alternating current (AC) measurement in tandem with a specially designed internal lock-in amplifier, the Model 372 can extract very small measurement signals from background noise. This allows for much lower excitation levels to be used when compared to traditional direct current (DC) systems, minimizing the amount of energy that is dissipated into the device under test.

The Model 372, originally designed as Lake Shore’s best temperature measurement and control bridge, is perfectly suited for highly precise resistance measurements. It covers an impressive resistance range, from Milli-Ohm to several dozens of Mega-Ohm

Features
  • Reduces measurement noise due to patented technology
  • Current source with integrated amplifier
  • Excitation current from 1 pA
  • Single channel AC resistance bridge with optional scanners
  • Benchtop unit with either front panel or remote control

Further information

Externally generated electronic noise can be a major cause of self-heating if it can couple into the device under test. Thankfully, multiple noise-rejection strategies have been implemented to reduce this effect substantially:

The patent (U.S. Patent #6,501,255, Dec., 2002, “Differential current source with active common mode reduction,” Lake Shore Cryotronics, Inc.) balanced noise-rejecting current source ensures that external signals have no path to ground through the measurement circuit, effectively making the Model 372 unaltered by these noise sources.

The measurement signal cables use a driven guard that reduces parasitic capacitance in the cables that connect a scanner to the Model 372. This helps to further balance the measurement network and bolster the integrity of the noise rejection circuitry.

All measurement circuitry is isolated from other instrument components, limiting the impact of any small electrical disturbances.

The AC frequency options used for the measurement signal are selected to be naturally resilient to the 50 Hz or 60 Hz line frequencies.

Model 372

Specifications

Model 372 AC Resistance Bridge

  • Measurement input: AC, 4-lead differential, resistance
  • Resistance: 2 mΩ to 63 MΩ in 22 ranges
  • Excitation current: 1 pA to 31 mA (RMS)
  • Maximum input voltage noise: 10 nV/rt(Hz) at 10 Hz
  • Number of display readings: 1 to 8
  • Interfaces: IEEE-488, USB, ethernet

Downloads

Model 372 AC Resistance bridge

Contact

Dr. Dario D'Ubaldo
Dr. Dario D'Ubaldo

Contact

Quantum Design s.r.l.

Via Francesco Sapori, 27
00143 Roma
Italy

Phone:+39 06 5004204
Fax:+39 06 5010389
E-mail:italy@qd-europe.com
Dr. Dario D'UbaldoSales Engineer
+39 06 5004204
Write e-mail