PhaseCam NIR, SWIR and MWIR interferometers
from 4DOperating at 632.8 nm (HeNe) as standard and at 532 nm optional, PhaseCam interferometers are also available with operating IR wavelengths from 1064 nm to 3.39 μm.
- Vibration Insensitive Dynamic Operation
- Single camera, high-speed optical phase sensor
- Turnkey instrument that includes the interferometer, advanced wavefront analysis software and complete, high-speed computer system
- 4Sight™ Data Analysis and Visualization Software
Further information
PhaseCam Twyman-Green infrared interferometers accurately measure concave, convex and afocal infrared components, as well as infrared telescopes and lens systems. PhaseCam systems are ideally suited for measuring infrared optics over long paths, for remote mounting in measurement towers or pressure vessels, and for other challenging test setups.
PhaseCam NIR and SWIR Infrared Interferometers
Small and lightweight, PhaseCam NIR and SWIR systems operate at wavelengths of 1.064 μm or 1.55 μm and incorporate patented Dynamic Interferometry® technology to acquire data thousands of times faster than a temporal phase shifting interferometer. Because acquisition time is so short, the systems can be used without vibration isolation in the most challenging environments.
These systems are ideal for long optical path-length measurement of large, focal optical systems such as concave telescope mirrors and lens systems, and for testing small aperture afocal components such as flat mirrors and collimators.
PhaseCam MWIR Infrared Interferometers
The PhaseCam Twyman-Green MWIR interferometer accurately measures concave, convex and afocal components, as well as optical systems, at mid-IR wavelengths. Its optical system enables measurement of both uncoated optics and high reflectors.
With its secondary output aperture on the side, we can provide an Off-Axis Parabolic Beam Expander, like the 150mm example shown.
The dual MWIR measurement path is uniquely
suited to maintaining two test set-ups. Use both in parallel, and significantly reduce set-up and alignment time for a specific test.
PhaseCam MWIR with beam expander Operating at 3.39 µm (other wavelengths available)
This 2:14 minute introduction of the PhaseCam MWIR with its remarkable features helps you see how well thought-out this instrument is. It adds so much value over the lifetime of its use.
How to measure optical components
4D Technology has been helping optics professionals to accurately measure optics for over 20 years: check the optical testing setups guide where they bring together all of that expertise, to help you make the best measurements in any environment!
Specifications
PhaseCam NIR
- Acquisition Mode: vibration insensitive dynamic interferometer
- Fiber-coupled head and laser source module; 5 m fiber length
- Wavelengths: 1.064 µm
- Camera: 4 Mpixels, 12-bit
- Motorized Controls: Focus, reference beam block, aperture block, contrast adjustment
- Software: 4Sight™ Focus included
- Size: < 39 cm (15.3 in) long
- Minimum Exposure: 30 μsec
- Beam Diameter: 7 mm FWHM
- Maximum Cavity Length: > 60 m
PhaseCam IR
- Acquisition Mode: vibration insensitive dynamic interferometer
- Wavelengths: 1.55 µm
- Camera: 512 x 512 pixels, 10-bit
- Motorized Controls: Focus, reference beam block, aperture block, contrast adjustment
- Software: 4Sight™ Focus included
- Size: < 41 cm (15.7 in) long
- Minimum Exposure: 30 μsec
- Beam Diameter: 9 mm FWHM
- Maximum Cavity Length: > 60 m
PhaseCam SWIR
- Acquisition Mode: vibration insensitive dynamic interferometer
- Wavelengths: 1.55 µm
- Camera: 512 x 512 pixels, 10-bit
- Motorized Controls: Focus, reference beam block, aperture block, contrast adjustment
- Software: 4Sight™ Focus included
- Size: < 41 cm (15.7 in) long
- Minimum Exposure: 30 μsec
- Beam Diameter: 9 mm FWHM
- Maximum Cavity Length: > 60 m
PhaseCam MWIR
- Acquisition Mode: Temporal Phase Shifting; Dynamic Interferometry optional
- Wavelengths: 3.39 µm; other wavelengths available
- Camera: 512 x 512 pixels
- Motorized Controls: Focus, reference beam block; main beam block
- Manual Controls: Visible alignment laser; measurement port selection
- Dual measurement ports: two apertures in one
- Software: 4Sight™ included
- Size: < 85 cm (33 in) long
- Minimum Exposure: 500 μsec
- Beam Diameter: 14 mm collimated
- Maximum Cavity Length: > 60 m
Applications
- Homogeneity measurement of IR materials
- Measure focal and afocal TWE in parallel
- TWE measurement of IR components, optical assemblies and telescopes
- Quality verification of optical components
- Meter-class telescopes
- Large primary mirrors and segmented mirrors
- Quality verification of optical components
- Vacuum and environmental chamber testing
- Production floor quality control
- Adaptive Optics and Moving Parts
Downloads
Videos
Contact
Navigation
Categories
Contact
Quantum Design s.r.l.
Via Francesco Sapori, 27
00143 Roma
Italy
Phone: | +39 06 5004204 |
Fax: | +39 06 5010389 |
E-mail: | italy@qd-europe.com |