Our partner 4DTechnology

PhaseCam NIR, SWIR and MWIR interferometers

from 4D

Operating at 632.8 nm (HeNe) as standard and at 532 nm optional, PhaseCam interferometers are also available with operating IR wavelengths from 1064 nm to 3.39 μm.

Features
  • Vibration Insensitive Dynamic Operation
  • Single camera, high-speed optical phase sensor
  • Turnkey instrument that includes the interferometer, advanced wavefront analysis software and complete, high-speed computer system
  • 4Sight™ Data Analysis and Visualization Software

Further information

PhaseCam Twyman-Green infrared interferometers accurately measure concave, convex and afocal infrared components, as well as infrared telescopes and lens systems. PhaseCam systems are ideally suited for measuring infrared optics over long paths, for remote mounting in measurement towers or pressure vessels, and for other challenging test setups.

PhaseCam NIR and SWIR Infrared Interferometers

Small and lightweight, PhaseCam NIR and SWIR systems operate at wavelengths of 1.064 μm or 1.55 μm and incorporate patented Dynamic Interferometry® technology to acquire data thousands of times faster than a temporal phase shifting interferometer. Because acquisition time is so short, the systems can be used without vibration isolation in the most challenging environments.

These systems are ideal for long optical path-length measurement of large, focal optical systems such as concave telescope mirrors and lens systems, and for testing small aperture afocal components such as flat mirrors and collimators.

PhaseCam MWIR Infrared Interferometers

The PhaseCam Twyman-Green MWIR interferometer accurately measures concave, convex and afocal components, as well as optical systems, at mid-IR wavelengths.  Its optical system enables measurement of both uncoated optics and high reflectors.

With its secondary output aperture on the side, we can provide an Off-Axis Parabolic Beam Expander, like the 150mm example shown.

The dual MWIR measurement path is uniquely

suited to maintaining two test set-ups. Use both in parallel, and significantly reduce set-up and alignment time for a specific test.

 

PhaseCam MWIR with beam expander Operating at 3.39 µm (other wavelengths available)

This 2:14 minute introduction of the PhaseCam MWIR with its remarkable features helps you see how well thought-out this instrument is. It adds so much value over the lifetime of its use.


How to measure optical components

4D Technology has been helping optics professionals to accurately measure optics for over 20 years: check the optical testing setups guide where they bring together all of that expertise, to help you make the best measurements in any environment!

OPTICAL TESTING SETUPS GUIDE

Specifications

PhaseCam NIR

  • Acquisition Mode: vibration insensitive dynamic interferometer
  • Fiber-coupled head and laser source module; 5 m fiber length
  • Wavelengths: 1.064 µm
  • Camera: 4 Mpixels, 12-bit
  • Motorized Controls: Focus, reference beam block, aperture block, contrast adjustment
  • Software: 4Sight™ Focus included
  • Size: < 39 cm (15.3 in) long
  • Minimum Exposure: 30 μsec
  • Beam Diameter: 7 mm FWHM
  • Maximum Cavity Length: > 60 m

PhaseCam IR

  • Acquisition Mode: vibration insensitive dynamic interferometer
  • Wavelengths: 1.55 µm
  • Camera: 512 x 512 pixels, 10-bit
  • Motorized Controls: Focus, reference beam block, aperture block, contrast adjustment
  • Software: 4Sight™ Focus included
  • Size: < 41 cm (15.7 in) long
  • Minimum Exposure: 30 μsec
  • Beam Diameter: 9 mm FWHM
  • Maximum Cavity Length: > 60 m

PhaseCam SWIR

  • Acquisition Mode: vibration insensitive dynamic interferometer
  • Wavelengths: 1.55 µm
  • Camera: 512 x 512 pixels, 10-bit
  • Motorized Controls: Focus, reference beam block, aperture block, contrast adjustment
  • Software: 4Sight™ Focus included
  • Size: < 41 cm (15.7 in) long
  • Minimum Exposure: 30 μsec
  • Beam Diameter: 9 mm FWHM
  • Maximum Cavity Length: > 60 m

PhaseCam MWIR

  • Acquisition Mode: Temporal Phase Shifting; Dynamic Interferometry optional
  • Wavelengths: 3.39 µm; other wavelengths available
  • Camera: 512 x 512 pixels
  • Motorized Controls: Focus, reference beam block; main beam block
  • Manual Controls: Visible alignment laser; measurement port selection
  • Dual measurement ports: two apertures in one
  • Software: 4Sight™ included
  • Size: < 85 cm (33 in) long
  • Minimum Exposure: 500 μsec
  • Beam Diameter: 14 mm collimated
  • Maximum Cavity Length: > 60 m

Applications

  • Homogeneity measurement of IR materials
  • Measure focal and afocal TWE in parallel
  • TWE measurement of IR components, optical assemblies and telescopes
  • Quality verification of optical components
  • Meter-class telescopes
  • Large primary mirrors and segmented mirrors
  • Quality verification of optical components
  • Vacuum and environmental chamber testing
  • Production floor quality control
  • Adaptive Optics and Moving Parts

Downloads

Vibration-Immune Metrology Drives Optical Communications
4 Sight Data Sheet
PhaseCam MWIR 3.39 Data Sheet
PhaseCam NIR Data Sheet
PhaseCam SWIR Data Sheet
Optical Testing Setups Guide

Videos

Dynamic Interferometry with 4D Technology

Contact

Ing. Alessandro Baratti
Ing. Alessandro Baratti

Related products

PhaseCam 4030 - Entry-level dynamic laser interferometer
The PhaseCam® 4030 is a compact, lightweight dynamic laser interferometer with simple, manual controls and vibration immunity for measurement of optics and optical systems. Flexible and low cost for ...
PhaseCam 6010 - Compact and lightweight dynamic laser interferometer
The PhaseCam 6010 is an extremely compact and lightweight dynamic laser interferometer for measurement of optics and optical systems. With an easy-to-position, fiber-coupled measurement head and ...
PhaseCam 6110 - Highest performance dynamic laser interferometer
Vibration-immune and only 13 inches in length, the PhaseCam 6110 features a high resolution 4MP imaging sensor and motorized controls, making it ideal for use in applications such as measuring large ...
Options and Accessories for PhaseCam Series Twyman-Green Interferometers
4D offers a broad array of diverging lens, beam expanders, mounts, cables, and other options for our PhaseCam Twyman-Green laser Interferometers. Optical Mechanical  ...
PhaseCam Vacuum Compatible - Patented vibration-immume interferometer for vacuum and thermal testing
The PhaseCam® Twyman-Green system provides accurate, quantitative measurement of surface shape, even in the presence of vibration or air turbulence. The vacuum-compatible PhaseCam includes fully ...

Contact

Quantum Design s.r.l.

Via Francesco Sapori, 27
00143 Roma
Italy

Phone:+39 06 5004204
Fax:+39 06 5010389
E-mail:italy@qd-europe.com
Ing. Alessandro BarattiProduct Manager
+39 06 5004204
Write e-mail